Service assistance to different kind of electronic devices, firmware update, schematics and more.....
Wednesday, November 21, 2018
Toshiba 40L2500, Toshiba 43L2500 – SMPS, Backlight inverter, LVDS, HDMI Audio schematic (circuit diagram)
Professional technician for all kind of electronic equipment. Doing since 1974.
Sunday, March 18, 2018
Electrolux ICON 36 inch Induction Cooktop – Error codes and causes
Electrolux
ICON 36 inch Induction Cooktop – Error codes and causes – Induction cooking
working principle – How to select cookware
How
Induction Cooking Works
Induction
cooking uses high frequency magnetic energy to heat the cooking utensil when it
is placed over the induction coil. The induction fields have no affect on
non magnetic surfaces such as paper, plastic, glass, ceramic, or non
ferrous metals like aluminum, copper etc.
An
induction cooking system requires two key components to operate.
The first component is the induction coil or element. This coil generates the magnetic induction field needed for induction cooking.
The first component is the induction coil or element. This coil generates the magnetic induction field needed for induction cooking.
The
second key component is the cooking utensil or pan with a bottom constructed of
material that will attract a magnet.
If
a magnet will not stick to the bottom of the pan it cannot be used for
induction cooking.
When
the proper type of pan is placed over the induction coil and the coil is
energized it generates a field of magnetic waves that cause the bottom of the
pan to heat.
Induction
cooking is highly efficient since the en ergy created by the induction fields
is not wasted by heating the glass and surrounding area of the cooktop surface.
Due
to this increased efficiency the contents of the pan are heated more quickly
than with gas burners or traditional radiant electric and coil elements.
Since
the induction fields heat only into the cooking utensil the surrounding surface
remains cooler than with traditional cooktops.
SELECTING
PROPER COOKWARE
When
selecting a pan to use for induction cooking it is important to know the
correct size of the pan in order to determine the proper cooking zone to be
used. The size of the magnetic portion of the pan bottom has a direct effect on
the cooking performance and efficiency of the cooking zone. Pan design and
construction vary widely as can be seen by the examples given below.
The
following illustrations show some of the variations found in the construction
of pan bottoms.
The
overall diameter of this pan is 9 inches if measured at the top portion. The
flat magnetic portion of the bottom (shaded in gray) is only 7 inches in
diameter. This pan would be considered to be a 7 inch pan and should be used on
a cooking zone appropriate for this size.
The
bottom of this pan is a non magnetic alloy with an encapsulated inner core of
magnetic material. The inner magnetic core is 1 inch smaller than the outer
dimension of the flat pan bottom. This pan will have different cooking
characteristics than the pan previously motioned. The effective cooking
diameter of this pan is 6 inches.
Pan
has a bottom of non magnetic alloy with a different shaped encapsulated inner
magnetic core. The illustration shows that the core is thinner near the outer
perimeter of the pan bottom and increases in thickness as it nears the center
of the pan. This type of pan will have different cooking characteristics than a
pan with a uniform core thickness.
ERROR
CODES CAUSES AND SOLUTIONS
ERROR
32 or 72
Low voltage output from 12V supply on filter board in the 3 cook zone induction module.
-Test all cables & connections on filter circuit board in the 3 zones induction module.
-Replace the filter circuit board in the 3 zones induction module .
-Replace generator circuit boards in the 3 zones induction module
ERROR 33 or 73
Improper voltage output from filter board in the 3 cook zone induction module. 34 Communication failure between filter board and power boards in the 3 cook zones induction module / left side cooking zones.
- Check cable between filter board X12 and generator board X10
- Replace the filter circuit board in the 3 zones induction module .
- Replace generator circuit board in the 3 zones induction module.
ERROR 35 or 75
AC input voltage too low in the 3 cook zones induction module.
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Replace the filter board in the 3 zones induction module
ERROR 36
Low voltage output from 12V supply on filter board in the 3 cook zone induction module.
-Test all cables & connections on filter circuit board in the 3 zones induction module.
-Replace the filter circuit board in the 3 zones induction module .
-Replace generator circuit boards in the 3 zones induction module
ERROR 33 or 73
Improper voltage output from filter board in the 3 cook zone induction module. 34 Communication failure between filter board and power boards in the 3 cook zones induction module / left side cooking zones.
- Check cable between filter board X12 and generator board X10
- Replace the filter circuit board in the 3 zones induction module .
- Replace generator circuit board in the 3 zones induction module.
ERROR 35 or 75
AC input voltage too low in the 3 cook zones induction module.
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Replace the filter board in the 3 zones induction module
ERROR 36
Communication
error between main touch control and filter board.
(3 cook zones induction module / left side cooking zones)
- Verify all communication cables between user interface and both induction generator modules.
- Replace the filter circuit board in the 3 zones induction module .
- Replace generator circuit board (dual) in the 3 zones induction module .
ERROR 37
(3 cook zones induction module / left side cooking zones)
- Verify all communication cables between user interface and both induction generator modules.
- Replace the filter circuit board in the 3 zones induction module .
- Replace generator circuit board (dual) in the 3 zones induction module .
ERROR 37
Heat
sink temperature sensor break
(3 zones induction module / left side cooking zones)
-Replace the generator circuit board (LF/LRl) in the 3 zones induction module
ERROR 39
(3 zones induction module / left side cooking zones)
-Replace the generator circuit board (LF/LRl) in the 3 zones induction module
ERROR 39
Configuration
mismatch between the User Interface and the induction module (occurs when one
of the 2 zone induction modules is replaced)
- To resolve this error, Press and hold WARM key, then press
Right Front zone ON key until beep (keep holding WARM) release Right Front zone ON key and press Left Front zone ON key until beep & config starts.
- Replace the filter circuit board in the 3 zones induction module .
ERROR 40
- To resolve this error, Press and hold WARM key, then press
Right Front zone ON key until beep (keep holding WARM) release Right Front zone ON key and press Left Front zone ON key until beep & config starts.
- Replace the filter circuit board in the 3 zones induction module .
ERROR 40
Communication
failure between main touch control and filter board.
- Verify AC input at the (2 zones induction housing) (X50 / X52).
- Verify Lin Bus harness cable from X68/X67 on right side filter board (2 zones induction module) to X20 on the left side filter board (3 zones induction module).
- Verify the lin communication wire at the timer input at X4/X5 pin 2.
ERROR 45
- Verify AC input at the (2 zones induction housing) (X50 / X52).
- Verify Lin Bus harness cable from X68/X67 on right side filter board (2 zones induction module) to X20 on the left side filter board (3 zones induction module).
- Verify the lin communication wire at the timer input at X4/X5 pin 2.
ERROR 45
Incoming
power supply low voltage - Verify incoming power supply to cooktop
ERROR 51
ERROR 51
LF
Element temperature sensor break - Verify Element temperature sensor is
correctly connected to the generator circuit board.
- Replace element if temperature sensor resistor value is not approximatively 1000 ohms (blue wires) at room temperature.
- Replace associated generator circuit board.
ERROR 52
- Replace element if temperature sensor resistor value is not approximatively 1000 ohms (blue wires) at room temperature.
- Replace associated generator circuit board.
ERROR 52
LR
Element temperature sensor break
ERROR 53
ERROR 53
Center
Element temperature sensor break
ERROR 54
ERROR 54
RR
Element temperature sensor break
ERROR 55
ERROR 55
RF
Element temperature sensor break
ERROR 60
ERROR 60
Touch:
general hardware error, keys - Replace main power touch control.
- Replace cook zones touch controls
- Replace cook zones touch controls
ERROR
61
LF
Element temperature sensor too hot - Verify cooktop ventilation is correct (airway
and fan).
- Verify Element temperature sensor is correctly connect to the generator circuit board.
- Replace element if temperature sensor resistor value is not approximatively 1000 ohms (blue wires) at room temperature.
- Replace associated generator circuit board.
ERROR 62
- Verify Element temperature sensor is correctly connect to the generator circuit board.
- Replace element if temperature sensor resistor value is not approximatively 1000 ohms (blue wires) at room temperature.
- Replace associated generator circuit board.
ERROR 62
LR
Element temperature sensor too hot
ERROR 63
ERROR 63
Center
Element temperature sensor too hot
ERROR 64
ERROR 64
RR
Element temperature sensor too hot
ERROR 65
ERROR 65
RF
Element temperature sensor too hot
ERROR
71
Internal
generator error, sync (center cooking zone)
- Test cables & connections on center generator circuit board (single).
- Replace the generator circuit board (single) in the 3 zones induction module .
ERROR 74
- Test cables & connections on center generator circuit board (single).
- Replace the generator circuit board (single) in the 3 zones induction module .
ERROR 74
Internal
generator error, communication (3 zones induction module)
- Check cable between filter board X13 and generator board X10
- Replace the filter circuit board in the 3 zones induction module
- Replace generator circuit board in the 3 zones induction module
ERROR 76
- Check cable between filter board X13 and generator board X10
- Replace the filter circuit board in the 3 zones induction module
- Replace generator circuit board in the 3 zones induction module
ERROR 76
Communication
Error in the 3 cook zones induction module for the center cooking zones.
- Verify all communication cables between user interface and both induction generator modules.
- Replace the filter circuit board in the 3 zones induction module .
- Replace generator circuit board for the center cook zone in the 3 zones induction module
ERROR 77
- Verify all communication cables between user interface and both induction generator modules.
- Replace the filter circuit board in the 3 zones induction module .
- Replace generator circuit board for the center cook zone in the 3 zones induction module
ERROR 77
Heat
sink temperature sensor break in the 3 cook zones induction module for the
center cooking zones.
- Replace generator circuit board for the center cook zone in the 3 zones induction module
ERROR 80
- Replace generator circuit board for the center cook zone in the 3 zones induction module
ERROR 80
Flash/Rom
check fail (EEPROM data) - Replace main power touch control
ERROR 90
ERROR 90
AC
input voltage too high in the 2 cook zones induction module.
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Replace the filter board in the 2 zones induction module
ERROR 91
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Replace the filter board in the 2 zones induction module
ERROR 91
Internal
generator error, sync in the 2 cook zones induction module.
- Test cables & connections on right generator circuit board.
- Replace the right side generator circuit board
ERROR 92
- Test cables & connections on right generator circuit board.
- Replace the right side generator circuit board
ERROR 92
12V
on the service section too low in the 2 cook zones induction module.
- Test all cables & connections on filter circuit board in the 2 zones induction module.
- Replace the filter circuit board in the 2 zones induction module .
- Replace generator circuit boards in the 2 zones induction module
ERROR 93
- Test all cables & connections on filter circuit board in the 2 zones induction module.
- Replace the filter circuit board in the 2 zones induction module .
- Replace generator circuit boards in the 2 zones induction module
ERROR 93
5V
overcurrent on the switched 5V on the service section (2 zones induction
module).
ERROR 94
ERROR 94
Internal
generator error, communication in the 2 cook zones induction module.
- Verify cable between filter board X58 and generator board X10 on the 2 zones induction module.
- Verify the heat sink thermal cutout in the 2 zones induction module is connected and resistance is approximately 0 ohms.
- Replace the filter circuit board in the 2 zones induction module.
- Replace generator circuit board in the 2 zones induction module
ERROR 95
- Verify cable between filter board X58 and generator board X10 on the 2 zones induction module.
- Verify the heat sink thermal cutout in the 2 zones induction module is connected and resistance is approximately 0 ohms.
- Replace the filter circuit board in the 2 zones induction module.
- Replace generator circuit board in the 2 zones induction module
ERROR 95
AC
input voltage too low in the 2 cook zones induction module.
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Verify the fuse resistance is approximatively 0 ohms in the 2 zones induction module.
- Replace the filter circuit board in the 2 zones induction module
ERROR 96
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Verify the fuse resistance is approximatively 0 ohms in the 2 zones induction module.
- Replace the filter circuit board in the 2 zones induction module
ERROR 96
Communication
Error in the 2 cook zones induction module.
- Verify all communication cables between user interface and both induction generator module.
- Replace the filter circuit board in the 2 zones induction module .
- Replace generator circuit board in the 2 zones induction module
ERROR 97
- Verify all communication cables between user interface and both induction generator module.
- Replace the filter circuit board in the 2 zones induction module .
- Replace generator circuit board in the 2 zones induction module
ERROR 97
Heat
sink temperature sensor break in the 2 cook zones induction module.
- Replace the generator circuit board in the 2 zones induction module
- Replace the generator circuit board in the 2 zones induction module
Professional technician for all kind of electronic equipment. Doing since 1974.
Monday, January 29, 2018
Sharp LC-46D62U, Sharp LC-52D62U – How to troubleshoot the No-Audio problem
Professional technician for all kind of electronic equipment. Doing since 1974.
How to troubleshoot for No Video problem – Sharp LC-46D62U, Sharp LC-52D62U – LCD Televisions
Professional technician for all kind of electronic equipment. Doing since 1974.
Sunday, July 16, 2017
LG21FG3RG-T9 CTV – how to enter the service mode, adjustments and circuit diagram
To protect the picture tube and
FBT, the average beam current an d peak beam current may not to high. The beam current limit information and High
Voltage(H.V) tracking information are derived from the H.V voltage winding of
T401 (point A).
1. The contrast and brightness reduction of RGB is proportional to the voltage on the pin 48 of IC501.
2. As the beam current(slow),and H.V (fast) are changes, the voltage of point A is changed.
3. By the increase of beam current ,the point A voltage is decreased and this information is fed to pin 48 of IC501.
* Contrast reduction begins when V49 is below than 3.1V.
* By the more increasing of the beam current , the V48 decreased and eventually when this voltage is less than 1.8V the brightness reduction is started.
The H drive output is open
collector and active low, [the H-out TR should conduct during the low period of
output.]1. The contrast and brightness reduction of RGB is proportional to the voltage on the pin 48 of IC501.
2. As the beam current(slow),and H.V (fast) are changes, the voltage of point A is changed.
3. By the increase of beam current ,the point A voltage is decreased and this information is fed to pin 48 of IC501.
* Contrast reduction begins when V49 is below than 3.1V.
* By the more increasing of the beam current , the V48 decreased and eventually when this voltage is less than 1.8V the brightness reduction is started.
2. Under normal operation condition the duty cycle of the output pulse is 50%.
3. To ensure a smooth start/stop behavior of the horizontal deflection and protect the H-out TR, there are 3 different condition of H-drive output.
During switch-on.
The horizontal output starts with the double frequency (31KHz) and with duty of 75%(off),25%(on).
After about 50mSec of switch-on.
The frequency is changed to normal value(15.625KHz) and duty cycle to 50%.
During switching-off.
Also the frequency is switched to the double value and R.G.B drive is set to Max. and after 100mSec R.G.B is set to Min. and 50mSec later the H drive is switch-off.
4. The H drive pulse from the MICOM (IC 501) is amplified by the horizontal drive circuit, to get sufficient base drive current for the high voltage switching TR (Q401)
3. To ensure a smooth start/stop behavior of the horizontal deflection and protect the H-out TR, there are 3 different condition of H-drive output.
During switch-on.
The horizontal output starts with the double frequency (31KHz) and with duty of 75%(off),25%(on).
After about 50mSec of switch-on.
The frequency is changed to normal value(15.625KHz) and duty cycle to 50%.
During switching-off.
Also the frequency is switched to the double value and R.G.B drive is set to Max. and after 100mSec R.G.B is set to Min. and 50mSec later the H drive is switch-off.
4. The H drive pulse from the MICOM (IC 501) is amplified by the horizontal drive circuit, to get sufficient base drive current for the high voltage switching TR (Q401)
How to enter the service mode
Press the OK buttons on both TV set and Remote Controller at the same time to get into SVC mode.
CDL Data Adjustment (LINE SVC-0)
1) Press the SVC button to get into the SVC-0 Mode.
2) Press the Channel UP/DOWN button to select CDLl2.
3) Press the Volume UP/DOWN button until the CDL data is the same as the Table below.
1) Press the SVC button to get into the SVC-0 Mode.
2) Press the Channel UP/DOWN button to select CDLl2.
3) Press the Volume UP/DOWN button until the CDL data is the same as the Table below.
4) Press the OK button to
memorize the data.
OPTION Data Adjustment (OPTION-l,OPTION-2)
1) Press OK buttons on both TV set and Remote Controller at the same time to get into SVC mode.
2) Press the Yellow button several times to find OPTION data.
3) Input the correspond OPTION data referring to Table below with the numeric buttons.
4) Press the OK button to memorize the data.
1) Press OK buttons on both TV set and Remote Controller at the same time to get into SVC mode.
2) Press the Yellow button several times to find OPTION data.
3) Input the correspond OPTION data referring to Table below with the numeric buttons.
4) Press the OK button to memorize the data.
AGC Adjustment (SERVICE 1)
1) Connect RF signal (70dBt0.2d8) and turn on the TV.
Standard adjustment Channel-EU 05 Ch. (frf= 175.25MHz)
2) Press the OK buttons on TV set and Remote Controller at the same time to get into SVC-0 mode.
3) In SVC-0 option, AGCTO is meant for AGC.
4) Press the Volume UP/DOWN button until the AGC Voltage is the same as the Table below.
5) Press the OK button to memorize the data.
Circuit diagram [SMPS and deflection]
Micom-Chroma schematic
White Balance Adjustment.(LINE
SVC-0)
NOTE : This adjustment should be
performed after screen voltage adjustment.
1) Tune the TV set to receive an 100% white pattern.
2) Press OK buttons on TV set and remote controller at the same time to get into SVC mode.
3) Use the CH CH Key to chose adjustment item.
4) Use the VOL VOL Key to change item data.
5) Adjustment.
a) Make the picture luminance 4.5 changing the " CONTRAST" and "BRIGHTNESS".
b) Adjust X data of low light with BLO-R and Y data with BLO-B.
c) Adjust X dada of High light RG and Y data with BG.
d) Repeat steps b & c until both low & high light hare same as shown below.
1) Tune the TV set to receive an 100% white pattern.
2) Press OK buttons on TV set and remote controller at the same time to get into SVC mode.
3) Use the CH CH Key to chose adjustment item.
4) Use the VOL VOL Key to change item data.
5) Adjustment.
a) Make the picture luminance 4.5 changing the " CONTRAST" and "BRIGHTNESS".
b) Adjust X data of low light with BLO-R and Y data with BLO-B.
c) Adjust X dada of High light RG and Y data with BG.
d) Repeat steps b & c until both low & high light hare same as shown below.
Screen voltage Adjustment
1) Connect the probe of oscilloscope
to the RK (Red Cathode) of CPT Board.
2) Set the oscilloscope to 50V/div and 20Us/div and after putting GND line upon the lowest grid line of the scope by pressing GND button, enter into DC mode.
3) Tune the TV set to receive a PAL-BG O5GH.
4) Adjust Screen Volume of FBT so that the (DC 150).
2) Set the oscilloscope to 50V/div and 20Us/div and after putting GND line upon the lowest grid line of the scope by pressing GND button, enter into DC mode.
3) Tune the TV set to receive a PAL-BG O5GH.
4) Adjust Screen Volume of FBT so that the (DC 150).
TDA7297
15+15w dual bridge amplifier
features
Wide supply voltage range (6.5v-18v)
Minimum external components
Internally fixed gain
Stand-by & mute functions
Thermal overload protection
Short circuit protection
15+15w dual bridge amplifier
features
Wide supply voltage range (6.5v-18v)
Minimum external components
Internally fixed gain
Stand-by & mute functions
Thermal overload protection
Short circuit protection
Professional technician for all kind of electronic equipment. Doing since 1974.
Subscribe to: