Electrolux
ICON 36 inch Induction Cooktop – Error codes and causes – Induction cooking
working principle – How to select cookware
How
Induction Cooking Works
Induction
cooking uses high frequency magnetic energy to heat the cooking utensil when it
is placed over the induction coil. The induction fields have no affect on
non magnetic surfaces such as paper, plastic, glass, ceramic, or non
ferrous metals like aluminum, copper etc.
An
induction cooking system requires two key components to operate.
The first component is the induction coil or element. This coil generates the magnetic induction field needed for induction cooking.
The first component is the induction coil or element. This coil generates the magnetic induction field needed for induction cooking.
The
second key component is the cooking utensil or pan with a bottom constructed of
material that will attract a magnet.
If
a magnet will not stick to the bottom of the pan it cannot be used for
induction cooking.
When
the proper type of pan is placed over the induction coil and the coil is
energized it generates a field of magnetic waves that cause the bottom of the
pan to heat.
Induction
cooking is highly efficient since the en ergy created by the induction fields
is not wasted by heating the glass and surrounding area of the cooktop surface.
Due
to this increased efficiency the contents of the pan are heated more quickly
than with gas burners or traditional radiant electric and coil elements.
Since
the induction fields heat only into the cooking utensil the surrounding surface
remains cooler than with traditional cooktops.
SELECTING
PROPER COOKWARE
When
selecting a pan to use for induction cooking it is important to know the
correct size of the pan in order to determine the proper cooking zone to be
used. The size of the magnetic portion of the pan bottom has a direct effect on
the cooking performance and efficiency of the cooking zone. Pan design and
construction vary widely as can be seen by the examples given below.
The
following illustrations show some of the variations found in the construction
of pan bottoms.
The
overall diameter of this pan is 9 inches if measured at the top portion. The
flat magnetic portion of the bottom (shaded in gray) is only 7 inches in
diameter. This pan would be considered to be a 7 inch pan and should be used on
a cooking zone appropriate for this size.
The
bottom of this pan is a non magnetic alloy with an encapsulated inner core of
magnetic material. The inner magnetic core is 1 inch smaller than the outer
dimension of the flat pan bottom. This pan will have different cooking
characteristics than the pan previously motioned. The effective cooking
diameter of this pan is 6 inches.
Pan
has a bottom of non magnetic alloy with a different shaped encapsulated inner
magnetic core. The illustration shows that the core is thinner near the outer
perimeter of the pan bottom and increases in thickness as it nears the center
of the pan. This type of pan will have different cooking characteristics than a
pan with a uniform core thickness.
ERROR
CODES CAUSES AND SOLUTIONS
ERROR
32 or 72
Low voltage output from 12V supply on filter board in the 3 cook zone induction module.
-Test all cables & connections on filter circuit board in the 3 zones induction module.
-Replace the filter circuit board in the 3 zones induction module .
-Replace generator circuit boards in the 3 zones induction module
ERROR 33 or 73
Improper voltage output from filter board in the 3 cook zone induction module. 34 Communication failure between filter board and power boards in the 3 cook zones induction module / left side cooking zones.
- Check cable between filter board X12 and generator board X10
- Replace the filter circuit board in the 3 zones induction module .
- Replace generator circuit board in the 3 zones induction module.
ERROR 35 or 75
AC input voltage too low in the 3 cook zones induction module.
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Replace the filter board in the 3 zones induction module
ERROR 36
Low voltage output from 12V supply on filter board in the 3 cook zone induction module.
-Test all cables & connections on filter circuit board in the 3 zones induction module.
-Replace the filter circuit board in the 3 zones induction module .
-Replace generator circuit boards in the 3 zones induction module
ERROR 33 or 73
Improper voltage output from filter board in the 3 cook zone induction module. 34 Communication failure between filter board and power boards in the 3 cook zones induction module / left side cooking zones.
- Check cable between filter board X12 and generator board X10
- Replace the filter circuit board in the 3 zones induction module .
- Replace generator circuit board in the 3 zones induction module.
ERROR 35 or 75
AC input voltage too low in the 3 cook zones induction module.
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Replace the filter board in the 3 zones induction module
ERROR 36
Communication
error between main touch control and filter board.
(3 cook zones induction module / left side cooking zones)
- Verify all communication cables between user interface and both induction generator modules.
- Replace the filter circuit board in the 3 zones induction module .
- Replace generator circuit board (dual) in the 3 zones induction module .
ERROR 37
(3 cook zones induction module / left side cooking zones)
- Verify all communication cables between user interface and both induction generator modules.
- Replace the filter circuit board in the 3 zones induction module .
- Replace generator circuit board (dual) in the 3 zones induction module .
ERROR 37
Heat
sink temperature sensor break
(3 zones induction module / left side cooking zones)
-Replace the generator circuit board (LF/LRl) in the 3 zones induction module
ERROR 39
(3 zones induction module / left side cooking zones)
-Replace the generator circuit board (LF/LRl) in the 3 zones induction module
ERROR 39
Configuration
mismatch between the User Interface and the induction module (occurs when one
of the 2 zone induction modules is replaced)
- To resolve this error, Press and hold WARM key, then press
Right Front zone ON key until beep (keep holding WARM) release Right Front zone ON key and press Left Front zone ON key until beep & config starts.
- Replace the filter circuit board in the 3 zones induction module .
ERROR 40
- To resolve this error, Press and hold WARM key, then press
Right Front zone ON key until beep (keep holding WARM) release Right Front zone ON key and press Left Front zone ON key until beep & config starts.
- Replace the filter circuit board in the 3 zones induction module .
ERROR 40
Communication
failure between main touch control and filter board.
- Verify AC input at the (2 zones induction housing) (X50 / X52).
- Verify Lin Bus harness cable from X68/X67 on right side filter board (2 zones induction module) to X20 on the left side filter board (3 zones induction module).
- Verify the lin communication wire at the timer input at X4/X5 pin 2.
ERROR 45
- Verify AC input at the (2 zones induction housing) (X50 / X52).
- Verify Lin Bus harness cable from X68/X67 on right side filter board (2 zones induction module) to X20 on the left side filter board (3 zones induction module).
- Verify the lin communication wire at the timer input at X4/X5 pin 2.
ERROR 45
Incoming
power supply low voltage - Verify incoming power supply to cooktop
ERROR 51
ERROR 51
LF
Element temperature sensor break - Verify Element temperature sensor is
correctly connected to the generator circuit board.
- Replace element if temperature sensor resistor value is not approximatively 1000 ohms (blue wires) at room temperature.
- Replace associated generator circuit board.
ERROR 52
- Replace element if temperature sensor resistor value is not approximatively 1000 ohms (blue wires) at room temperature.
- Replace associated generator circuit board.
ERROR 52
LR
Element temperature sensor break
ERROR 53
ERROR 53
Center
Element temperature sensor break
ERROR 54
ERROR 54
RR
Element temperature sensor break
ERROR 55
ERROR 55
RF
Element temperature sensor break
ERROR 60
ERROR 60
Touch:
general hardware error, keys - Replace main power touch control.
- Replace cook zones touch controls
- Replace cook zones touch controls
ERROR
61
LF
Element temperature sensor too hot - Verify cooktop ventilation is correct (airway
and fan).
- Verify Element temperature sensor is correctly connect to the generator circuit board.
- Replace element if temperature sensor resistor value is not approximatively 1000 ohms (blue wires) at room temperature.
- Replace associated generator circuit board.
ERROR 62
- Verify Element temperature sensor is correctly connect to the generator circuit board.
- Replace element if temperature sensor resistor value is not approximatively 1000 ohms (blue wires) at room temperature.
- Replace associated generator circuit board.
ERROR 62
LR
Element temperature sensor too hot
ERROR 63
ERROR 63
Center
Element temperature sensor too hot
ERROR 64
ERROR 64
RR
Element temperature sensor too hot
ERROR 65
ERROR 65
RF
Element temperature sensor too hot
ERROR
71
Internal
generator error, sync (center cooking zone)
- Test cables & connections on center generator circuit board (single).
- Replace the generator circuit board (single) in the 3 zones induction module .
ERROR 74
- Test cables & connections on center generator circuit board (single).
- Replace the generator circuit board (single) in the 3 zones induction module .
ERROR 74
Internal
generator error, communication (3 zones induction module)
- Check cable between filter board X13 and generator board X10
- Replace the filter circuit board in the 3 zones induction module
- Replace generator circuit board in the 3 zones induction module
ERROR 76
- Check cable between filter board X13 and generator board X10
- Replace the filter circuit board in the 3 zones induction module
- Replace generator circuit board in the 3 zones induction module
ERROR 76
Communication
Error in the 3 cook zones induction module for the center cooking zones.
- Verify all communication cables between user interface and both induction generator modules.
- Replace the filter circuit board in the 3 zones induction module .
- Replace generator circuit board for the center cook zone in the 3 zones induction module
ERROR 77
- Verify all communication cables between user interface and both induction generator modules.
- Replace the filter circuit board in the 3 zones induction module .
- Replace generator circuit board for the center cook zone in the 3 zones induction module
ERROR 77
Heat
sink temperature sensor break in the 3 cook zones induction module for the
center cooking zones.
- Replace generator circuit board for the center cook zone in the 3 zones induction module
ERROR 80
- Replace generator circuit board for the center cook zone in the 3 zones induction module
ERROR 80
Flash/Rom
check fail (EEPROM data) - Replace main power touch control
ERROR 90
ERROR 90
AC
input voltage too high in the 2 cook zones induction module.
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Replace the filter board in the 2 zones induction module
ERROR 91
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Replace the filter board in the 2 zones induction module
ERROR 91
Internal
generator error, sync in the 2 cook zones induction module.
- Test cables & connections on right generator circuit board.
- Replace the right side generator circuit board
ERROR 92
- Test cables & connections on right generator circuit board.
- Replace the right side generator circuit board
ERROR 92
12V
on the service section too low in the 2 cook zones induction module.
- Test all cables & connections on filter circuit board in the 2 zones induction module.
- Replace the filter circuit board in the 2 zones induction module .
- Replace generator circuit boards in the 2 zones induction module
ERROR 93
- Test all cables & connections on filter circuit board in the 2 zones induction module.
- Replace the filter circuit board in the 2 zones induction module .
- Replace generator circuit boards in the 2 zones induction module
ERROR 93
5V
overcurrent on the switched 5V on the service section (2 zones induction
module).
ERROR 94
ERROR 94
Internal
generator error, communication in the 2 cook zones induction module.
- Verify cable between filter board X58 and generator board X10 on the 2 zones induction module.
- Verify the heat sink thermal cutout in the 2 zones induction module is connected and resistance is approximately 0 ohms.
- Replace the filter circuit board in the 2 zones induction module.
- Replace generator circuit board in the 2 zones induction module
ERROR 95
- Verify cable between filter board X58 and generator board X10 on the 2 zones induction module.
- Verify the heat sink thermal cutout in the 2 zones induction module is connected and resistance is approximately 0 ohms.
- Replace the filter circuit board in the 2 zones induction module.
- Replace generator circuit board in the 2 zones induction module
ERROR 95
AC
input voltage too low in the 2 cook zones induction module.
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Verify the fuse resistance is approximatively 0 ohms in the 2 zones induction module.
- Replace the filter circuit board in the 2 zones induction module
ERROR 96
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Verify the fuse resistance is approximatively 0 ohms in the 2 zones induction module.
- Replace the filter circuit board in the 2 zones induction module
ERROR 96
Communication
Error in the 2 cook zones induction module.
- Verify all communication cables between user interface and both induction generator module.
- Replace the filter circuit board in the 2 zones induction module .
- Replace generator circuit board in the 2 zones induction module
ERROR 97
- Verify all communication cables between user interface and both induction generator module.
- Replace the filter circuit board in the 2 zones induction module .
- Replace generator circuit board in the 2 zones induction module
ERROR 97
Heat
sink temperature sensor break in the 2 cook zones induction module.
- Replace the generator circuit board in the 2 zones induction module
- Replace the generator circuit board in the 2 zones induction module